47 auto select request, External controls, Ack continued – Vidikron VP-60 User Manual
Page 105: Function, Transmission data
104
ACK continued ...
7FH
60H
80H
45H
0CH
DATA00 to DATA11
CKS
DATA07: BRIGHT Gain
E0H: -32
|
FFH: -01
00H: 0
01H: +01
|
20H: +32
DATA08: RED Gain (Drive)
D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA09: GREEN Gain (Drive)
D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA10: BLUE Gain (Drive)
D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA11: WHITE BAL.
00H: 5400K
01H: 6500K
02H: 8500K
03H: 9300K
47 AUTO SELECT REQUEST
Function
The external control equipment inquires the current combinations of audio and video
inputs for the plasma monitor.
Transmission Data
1FH
80H
60H
6FH
00H
CKS
ACK
7FH
60H
80H
6FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: AUDIO 1
01H - 0CH: VISUAL INPUT DATA
DATA01: AUDIO 2
01H - 0CH: VISUAL INPUT DATA
DATA02: AUDIO 3
01H - 0CH: VISUAL INPUT DATA
VISUAL INPUT DATA
01H:
Video 1
02H:
Video 2
03H:
Video 3
05H:
HD (HD1 or DTV or DTV1)
06H:
HD2 (DTV2)
07H:
RGB 1 /PC1
08H:
RGB 2 /PC2
0CH:
RGB 3 /PC3
External Controls