37 factory, 38 audio select set, 98 external controls – Vidikron VP-60 User Manual

Page 99

Advertising
background image

98

External Controls

37 FACTORY

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH

80H

60H

54H

00H

CKS

ACK

3FH

60H

80H

54H

00H

CKS

38 AUDIO SELECT SET

Function

The external control equipment sets combinations of audio and video inputs for the

plasma monitor.

Transmission Data

DFH

80H

60H

70H

02H

DATA00 DATA01 CKS

DATA00: AUDIO

01H: AUDIO 1
02H: AUDIO 2
03H: AUDIO 3

DATA01: VISUAL INPUT

01H: Video 1
02H: Video 2
03H: Video 3
05H: HD

(HD1 or DVD or DVD1)

06H: HD2 (DTV2)
07H: RGB 1/PC1
08H: RGB 2/PC2
0CH: RGB 3/PC3

ACK

The plasma monitor returns the following ACK when the input is switched

.

3FH

60H

80H

70H

00H

CKS

* The plasma monitor returns “Not Available” when selecting the video input same as the

one set at one of the AUDIO 1 to 3.

Example:

The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or

VIDEO3 after VIDEO1 has been set to AUDIO1.