16 BLUE GAIN DATA

Function

The external control equipment changes the BLUE gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

DATA02: BLUE Gain 1 (Offset)

D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30

DATA03

BLUE Gain 2 (Drive)

D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

17 VID NR MODE SET

Function

The external control equipment sets the VID NR (Noise Reduction) mode of the plasma

monitor.

Transmission Data

DFH

80H

60H

C0H

01H

DATA00 CKS

DATA00: 01H: VID NR OFF

02H: VID NR-1
03H: VID NR-2
04H: VID NR-3

ACK

7FH

60H

80H

C0H

01H

DATA00 CKS

DATA00: 01H: VID NR OFF

02H: VID NR-1

03H: VID NR-2

04H: VID NR-3