48 FAILURE MODE REQUEST

Function

The external control equipment inquires the detection of failures of the plasma monitor.

Transmission Data

1FH

80H

60H

3FH

00H

CKS

ACK

The plasma monitor returns the following ACK:

7FH

60H

80H

3FH

02H

DATA00 DATA01 CKS

DATA00: FAILURE MODE 1

Bit 0:

PDP MODULE
0: Abnormal
1: Normal

Bit 1:

1: fixed (backup)

Bit 2:

TEMPERATURE
0: Abnormal
1: Normal

Bit 3:

1: fixed (backup)

Bit 4:

TEMPERATURE SENSOR
0: Abnormal
1: Normal

Bit 5:

1: fixed (backup)

Bit 6:

1: fixed (backup)

Bit 7:

1: fixed (backup)

DATA01: FAILURE MODE 2

1: fixed (backup)

49 MODEL NAME REQUEST

Function

The external control equipment inquires the product code of the plasma monitor.

Transmission Data

1FH

80H

60H

17H

00H

CKS

ACK

The plasma monitor returns the following ACK:

7FH

60H

80H

17H

0CH

DATA00 to DATA11

CKS

DATA00: 1st character of the product code

DATA01: 2nd character of the product code

|

DATA11: 12th character of the product code

NOTE:

Received Data (Hex)

Corresponding Character

00H

0

01H

1

|

|

08H

8

09H

9

10H

A

11H

B

12H

C

|

|

28H

Y

29H

Z

80H

- (Hyphen)

96H

(Blank)

If there are fewer than 12 characters in the product code,

product code would be padded right with blanks.