Specifications

975-0170-01-01

A–3

Charger Specifications

All charging specifications are at nominal conditions: ambient
temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise
specified.

Table A-2 Charger Specifications

Charging method

Three-stage charge (Bulk, Absorption, Float)

Two-stage charge (Bulk, Absorption)

The default charging method is three-stage.

Without a battery temperature
sensor

Three settings with the following temperature
values:

Cool 50 °F (10 °C)

Warm 77 °F (25 °C)

Hot 104 °F (40 °C)

The default value for this setting is Hot, and it can
only be changed by a dealer, factory, or service
centre.

With a battery temperature
sensor

The temperature compensation coefficients on a
12 volt battery are as follows:

Flooded: 27 mV × (25 °C – BTS °C)

Gel: 27 mV × (25 °C – BTS °C)

AGM: 21 mV × (25 °C – BTS °C)

Equalization cycle

Yes, manual via System Control Panel

Number of independent battery
banks

1

Battery bank size settings

50 – 2000 Ahr

Battery type settings

Flooded, AGM, Gel, Custom

Power factor corrected charging Yes

Input power factor at full
charge rate

> 0.95

AC input voltage

90 – 135 VAC

AC input frequency

60 Hz nominal, 55 – 65 Hz operating range

Minimum battery voltage

3.0 VDC

Maximum DC output voltage

16.0 VDC

Charger efficiency

≥ 85%

Maximum charge current

150 A