System Start-up Check

To test inverting and charging from the RS3000 front panel:

1. Disconnect AC power from inverter input by opening the breaker or

disconnect. Press the Inverter Enable button on the RS3000. The
Inverter On light illuminates.

2. Place a load on the inverter. For example, plug a 100 watt light bulb

into an outlet that the inverter is powering and make sure it works.
The inverter should run the load using battery power.

3. To test the charger, reconnect the AC input power to allow AC to the

AC input. The Charger On light should illuminate after a brief delay.
Any AC loads previously powered by the inverter will also work at
this time.

4. Remove the AC input power. The inverter/charger should transfer to

invert mode immediately. (The transfer relay will make a clicking
sound and the Inverter On light will illuminate.) Loads should
continue to operate uninterrupted.

If any part of this test fails, determine the cause before using the unit.
Consult the “Troubleshooting” chapter starting on page 4–1.

Viewing the Firmware Revision Number

You may need to view the firmware revision number of the RS3000 when
troubleshooting the unit with authorized service personnel.

To view the firmware revision number:

1. On the Select Device menu, use the down arrow button to highlight

System and press Enter.

The System Settings menu appears.

2. Press the down arrow button to highlight View Device info and press

Enter.

The Device Info screen appears.

3. Press the down arrow button until the RS3000 screen appears.

The number opposite “F/W Rev.” is the firmware revision number.

4. Press Exit to return to the System Settings menu.

WARNING

Review the “Important Safety Instructions” on page vii before operating the
inverter/charger.