Rs3000 features, Front panel features, Front panel features –7 – Xantrex Technology RS3000 User Manual

Page 25: Figure 1-2, Front panel of the rs3000

Advertising
background image

Introduction

975-0170-01-01

1–7

RS3000 Features

Front Panel Features

Before you begin to operate the RS3000, review the front panel features
shown in Figure 1-2 and described in Table 1-1. A detailed view of the
lights and buttons on the front panel is shown in Figure 1-3 and described
in Table 1-2.

Figure 1-2 Front Panel of the RS3000

Table 1-1 Front Panel Features

Feature

Description

1

AC wiring compartment access panel provides access to the terminal block for
wiring the AC input and AC output.

2

AC knockouts provide access for AC input and AC output wiring. A total of four
knockouts are provided on the unit: two on the front and one on each side (not
shown).

3

Mounting flanges are used for mounting the unit. A total of six flanges are
provided on the unit.

4

Fans are located on the top of the unit and the bottom of the unit.

Top external fan is an intake fan that activates when the internal temperature of
the inverter/charger increases. The fan speed varies with the internal temperature
and turns off when the inverter/charger cools down. (This internal temperature
may be caused by heat in the inverter/charger or by high ambient temperature.)

Top internal fan (not shown) is an exhaust fan and runs continuously if the unit is
inverting or charging.

Bottom internal fan (not shown) is an exhaust fan and runs continuously if the
unit is inverting or charging.

2

3

2

1

2

4

2

3