Power share, Power share –13 – Xantrex Technology RS3000 User Manual

Page 63

Advertising
background image

Configuration

975-0170-01-01

3–13

Outcome

If the AC is qualified, the charger operates. If the AC is not qualified, then
the charger will not operate until AC qualifies.

See “Force Charge” on page 3–23 for information on automatic charging.

Power Share

Configurable setting

Power Share is a configurable setting that you set to match to the breaker
rating on the AC input. This setting is used to ensure that the charger
limits its output to try to prevent nuisance tripping of the AC input
breaker due to the total current drawn by the charger and your other AC
loads. For more information on this feature, see “Power Share” on
page 2–12.

In the example shown, Power Share is set to 30A.

You can adjust the power share settings as follows:

When to use

Set the Power Share setting to match the AC input breaker. Use this
setting when connecting to an AC source. If using multiple AC sources
via an AC transfer switch, adjust this setting to the smaller AC breaker
size.

Outcome

Setting the value higher than the AC source’s external breaker could
cause the external breaker to trip.

Power Share

[30A]

Range of values

Increment

Default

5 to 50 amps

5 amps

30 amps

Advertising