3. Foundation Requirements

14

PNEG-1510 Top Dry 24', 30' and 36' Manual Batch

Frost Free Foundation Top Dry Bins

Diameter of Bin: 24'

Corrugation : 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (Ft.)

Length #6

Bar (Ft.)

Total Cu. Yds.

Concrete

6

1'-1"

2

12'-9"

900

600

200

13

7, 8

1'-9"

2

12'-9"

900

600

200

15

9, 10

2'-6"

3

13'-2"

900

600

400

18

Diameter of Bin: 30'

Corrugation : 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (Ft.)

Length #6

Bar (Ft.)

Total Cu. Yds.

Concrete

6

1'-2"

2

15'-9"

1400

900

200

19

7, 8

1'-10"

2

15'-10"

1400

900

200

21

9, 10

2'-8"

3

16'-1"

1400

900

500

25

11

3'-8"

4

16'-5"

1400

900

700

29

Diameter of Bin: 36'

Corrugation : 4.00"

Ring #

B

N

Outside

Radius

Sq. Ft. Mesh

6 x 6 - 6/6

Optional #4

18" x 18" Grid (Ft.)

Length #6

Bar (Ft.)

Total Cu. Yds.

Concrete

6

1'-3"

2

18'-9"

2000

1300

300

26

7, 8

2'-0"

2

18'-11"

2000

1300

400

30

9, 10

2'-10"

3

19'-0"

2000

1300

600

33

11, 12

3'-11"

4

19'-6"

2000

1300

900

39