6. Stiffener Details

PNEG-1510 Top Dry 24', 30' and 36' Manual Batch

31

Top Stiffener Starting Location

Refer to

Figure 6B

, for proper location of top stiffeners. On the overlap of the stiffeners and on the

splice, use 3/8" x 1" hex bolts, a washer on the nut side connection. Refer to sidewall gauges and
stiffener usage.

All stiffeners are outside the bin wall. Use 5/16" x 3/4" grade 5 bin bolts with head and neoprene washer
to the inside of the bin wall. Refer to proper

Chart on Page 29

and

Figure 6A on Page 30

for proper location

of stiffeners and sidewall sheets.