C” channel installation, “c” channels – Grain Systems PNEG-1510 User Manual

Page 36

Advertising
background image

7. “C” Channels

36

PNEG-1510 Top Dry 24', 30' and 36' Manual Batch

“C” Channel Installation

Fasten the rolled “C” eave members to the wall brackets in the upper two (2) holes of the top set of
three (3) holes leaving the bolts loose.

Install the splice plates at the rolled “C” eave member seams using 3/8" x 1" flanged hex bolts and nuts.
Install bolts as shown

in Figure 7C

. Tighten all bolts.

Figure 7B “C” Channel Attachment

Figure 7C

Nominal Diameter of Tank (Ft.)

Part # “A”

24'

TD-100678

30'

TD-100643

36'

TD-100731

Advertising