5. Assembly

32

PNEG-720-G2 12" and 16" Series II Sweep

Install Reducer Mounting Plate and Reducer

A. Attach the C-Face reducer to the mounting plate using four (4) 1/2"-13 x 1-1/4" hex bolts and

lock washers.

(See Figure 5M.)

B. Fasten the reducer mounting plate to the tail section plate using four (4) 5/8"-11 x 6" all-thread rods

and sixteen (16) hex nuts. Adjust the mounting plate as close as possible to the tail section plate.

Figure 5M

CAUTION

The gear reducer is NOT filled with oil from the factory. For gear reducer
specifications and oil fill recommendations, refer to Owner’s manual supplied with
the reducer or the lubrication information in the

Lubrication Section on Page 68

of

this manual.

CAUTION

The tractor drive gear reducer has a drain plug in the bottom of the housing. Make
sure the drain plug is flush or slightly under the surface of the mounting face. If it is
not, the plug will not allow the reducer to set flat on the mounting plate and could
cause the motor to seize.

THIS TYPE OF DAMAGE IS NOT COVERED BY THE WARRANTY.