Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-720-G2 User Manual

Page 48

Advertising
background image

5. Assembly

48

PNEG-720-G2 12" and 16" Series II Sweep

L. Attach the 3/4" rigid conduit assembly to the sweep using the 5/16"-18 x 3/4" studs welded to the

sweep using 1" conduit clamps, lock washers and hex nuts.

M. Run the 14 AWG stranded wires into the drive motor and fasten the 3/4" x 48" liquid-tight flex conduit

to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a reducer
bushing not supplied with the sweep. Connect the leads as required.

(See Figure 5AF.)

Figure 5AF

N. Run the 10 AWG stranded wires into the auger motor and fasten the 3/4" x 40" liquid-tight flex conduit

to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a reducer
bushing not supplied with the sweep. Connect the leads as required.

NOTE: If you are using the pivot kit, skip to

Page 52

and refer to “

Step A on Page 52

”.

O. Tractor Drive: Slide a 5/8" to 3/4" cord connector six inches (6") onto one end of the

14 AWG/4 wire cords and fasten it to the junction box using one 1" to 3/4" reducer bushings. Connect
the leads as required.

Sweep Drive all 12" and 16" under 105 Model: Slide a 5/8" to 3/4" cord connector six inches (6")
onto one end of the 10 AWG/4 wire cords and fasten it to the junction box using one 1" to 3/4" reducer
bushings. Connect the leads as required.

Sweep Drive all 16" 105 Model and over: Slide a 5/8" to 3/4" cord connector six inches (6")
onto one end of the 8 AWG/4 wire cords and fasten it to the junction box using one 1" to
3/4" reducer bushings. Connect the leads as required.

P. Slide a 1/2" to 5/8" cord connector six inches (6") onto the end of the 14 AWG/3 wire cord

and fasten it to the junction box using one 1" to 3/4" reducer bushings. Connect the leads
as required.

Q. Use the plugs provided with the junction boxes to close the holes not being used.

Advertising