4.3 ULDP Function Typical Examples

Fiber Cross Connection

In the network topology in Graph, port g1/0/1 and port g1/0/2 of switch A as well as port g1/0/3

and port g1/0/4 of switch B are all fiber ports. And the connection is cross connection. The

physical layer is connected and works normally, but the data link layer is abnormal. ULDP can

discover and disable this kind of error state of link. The final result is that port g1/0/1, g1/0/2 of

switch A and port g1/0/3, g1/0/4 of switch B are all shut down by ULDP. Only when the
connection is correct, can the ports work normally (won’t be shut down).

Switch A configuration sequence:

SwitchA(config)#uldp enable

SwitchA(config)#interface ethernet 1/0/1

SwitchA (Config-If-Ethernet1/0/1)#uldp enable

SwitchA (Config-If-Ethernet1/0/1)#exit

SwitchA(config)#interface ethernet1/0/2

SwitchA(Config-If-Ethernet1/0/2)#uldp enable

Switch B configuration sequence:

SwitchB(config)#uldp enable

SwitchB(config)#interface ethernet1/0/3

SwitchB(Config-If-Ethernet1/0/3)#uldp enable

SwitchB(Config-If-Ethernet1/0/3)#exit

SwitchB(config)#interface ethernet1/0/4

SwitchB(Config-If-Ethernet1/0/4)#uldp enable

As a result, port g1/0/1, g1/0/2 of switch A are all shut down by ULDP, and there is notification

information on the CRT terminal of PC1.

%Oct 29 11:09:50 2007 A unidirectional link is detected! Port Ethernet1/0/1 need to be shutted

down!

g1/0/2

Switch B

g1/0/4

g1/0/3

g1/0/1

Switch A

PC1

PC2