34.3 ULPP Typical Examples

34.3.1 ULPP Typical Example1

ULPP typical example1

The above topology is the typical application environment of ULPP protocol.

SwitchA has two uplinks, they are SwitchB and SwitchC. When any protocols are not enabled,

this topology forms a ring. For avoiding the loopback, SwitchA can configure ULPP protocol,

the master port and the slave port of ULPP group. When both master port and slave port are

up, the slave port will be set as standby state and will not forward the data packets. When the

master port is down, the slave port will be set as forwarding state and switch to the uplink.

SwitchB and SwitchC can enable the command that receives the flush packets, it is used to

associate with ULPP protocol running of SwitchA to switch the uplink immediately and reduce

the switch delay.

When configuring ULPP protocol of SwitchA, first, create a ULPP group and configure the

protection VLAN of this group as vlan10, then configure interface Ethernet 1/0/1 as the master

port, interface Ethernet 1/0/2 as the slave port, the control VLAN as 10. SwitchB and SwitchC

configure the flush packets that receive ULPP.

SwitchA configuration task list:

Switch(Config)#vlan 10

Switch(Config-vlan10)#switchport interface ethernet 1/0/1; 1/0/2

Switch(Config-vlan10)#exit

Switch(Config)#spanning-tree mst configuration

Switch(Config-Mstp-Region)#instance 1 vlan 10

Switch(Config-Mstp-Region)#exit

Switch(Config)#ulpp group 1

Switch(ulpp-group-1)#protect vlan-reference-instance 1

Switch(ulpp-group-1)#control vlan 10

SwitchB

E1/0/1

SwitchD

SwitchA

E1/0/2 SwitchC

E1/0/2

E1/0/1

Advertising