34.3.2 ULPP Typical Example2

ULPP typical example2

ULPP can implement the VLAN-based load balance. As the picture illustrated, SwitchA

configures two ULPP groups: port E1/0/1 is the master port and port 1/0/2 is the slave port in

group1, port 1/0/2 is the master port and port 1/0/1 is the slave port in group2. The VLANs

protected by group1 are 1-100 and by group2 are 101-200. Here both port E1/0/1 and port

E1/0/2 at the forwarding state, the master port and the slave port mutually backup, respectively

forward the packets of different VLAN ranges. When port E1/0/1 has the problem, the traffic of

VLAN 1-200 are forwarded by port E1/0/2. When port E1/0/1 is recovering the normal state,

still port E1/0/2 forwards the data of VLAN 101-200, the data of VLAN 1-100 are switched to

port E1/0/1 to forward.

SwitchA configuration task list:

Switch(Config)#spanning-tree mst configuration

Switch(Config-Mstp-Region)#instance 1 vlan 1-100

Switch(Config-Mstp-Region)#instance 2 vlan 101-200

Switch(Config-Mstp-Region)#exit

Switch(Config)#ulpp group 1

Switch(ulpp-group-1)#protect vlan-reference-instance 1

Switch(ulpp-group-1)#preemption mode

Switch(ulpp-group-1)#exit

Switch(Config)#ulpp group 2

Switch(ulpp-group-2)#protect vlan-reference-instance 2

Switch(ulpp-group-1)#preemption mode

Switch(ulpp-group-2)#exit

Switch(Config)#interface ethernet 1/0/1

Switch(config-If-Ethernet1/0/1)#switchport mode trunk

SwitchB

E1/0/1

SwitchD

SwitchA

E1/0/2 SwitchC

E1/0/2

E1/0/