Clear-Com HX System Frames User Manual

Page 124

Advertising
background image


11. The Assign New Configuration File dialog asks you to select an FPGA image for the first

device in the chain or to bypass that device.

In this example procedure, the first device will be bypassed and an FPGA image will be
assigned to the second device .

• For the first device, press Bypass.

• For the second device, select the FPGA image:


Hardware DVD > Eclipse HX-Omega-Median-Delta > xxxxxxZ - E-MADI FPGA >
xxxxxxZx.mcs
and xxxxxxZx.cfi

Where x represents a digit in the product / file number.

Note:

When upgrading the E-MADI64 FPGA, both the *.mcs and *.cfi file are required. The *.cfi and
*.mcs file are available from the same location. The user does not have to do anything else,
as the tools find the files.

12. A summary dialog is presented. For the selected device, ensure that the Erase the Entire

Device and Verify flags are set. Click OK.


Figure 84: Example Xilinx device programming properties

13. In Impact Processes, double click program.

The upgrade (programming) starts, and takes approximately 2 minutes to complete. When the
upgrade is complete, the Program Succeeded message is displayed in the main window.

14. Power down the UUT.

117

Eclipse HX Upgrade Guide

Advertising
This manual is related to the following products: