13.2.2 Manually upgrading I-Series panel application code

Before you manually upgrade the application code for I-Series panels, ensure that you have the
following equipment:

• An I-Series serial interconnect lead.

• RS232/RS422 adaptor (see Figure 86: Example converter cable).

• An installed Tera Term application.

• A paperclip or small flat blade screwdriver to access maintenance button on the rear

of the I-Series panel.


Tera Term uses a special file with the updated I-Series or E-station application code, instead of an
*.fwp file. The file has an *.s19 file extension and the specific files can be found on the software DVD:

Software DVD > Panel Software > I-Series > xxxxxxZ-I-Series App

Software DVD > Panel Software > I-Series > xxxxxxZ-E-Station App


Where xxxxxxZ represents the product number.

Tip:

An I-Series or E-station with either no firmware installed or corrupted firmware may be repaired

through an upgrade (the station will display Display Module Test, Press All Buttons 3X).

To manually upgrade the I-Series panel application code:

1. Install Tera Term. Third party software is available from either of the Eclipse HX 7.5 DVDs:

Software DVD > 3rd_Party_Software > Teraterm

Hardware DVD > 3rd_Party_Software > Teraterm

Tip:

For more information about installing Tera Term, see Appendix F: Tera Term