Clear-Com HX System Frames User Manual

Page 134

Advertising
background image

4. From the Tera Term main screen select Setup > Serial port….

The serial port setup screen should now be visible. Configure Tera Term with the following
settings:

Field

Setting

Baud

19200

Data

8 bit

Parity

None

Stop

1 bit

Flow Control

None

Table 37: Serial port setup screen settings


Note:

Do not configure (ignore) the Transmit delay settings.

Click OK.

5. Power up the I-Series panel into maintenance mode by first holding in the recessed button

found on the rear panel during a simultaneous AC power up.

The reset button must be held in until all front panel keys turn

bright red

and the front panel

display modules show the message Display Module Test’, Press All Buttons 3x.

Tip:

If the recessed button cannot easily be accessed, use a bent paper clip or small flat

blade screwdriver to press the button in.

Figure 91: Module display message

127

Eclipse HX Upgrade Guide