6.6 Checking the Eclipse HX-PiCo application code and

MVX code versions

You can check both the Eclipse HX-PiCo application code and MVX code versions by going to EHX>
Matrix Event Log > Matrix Overview
.

You can also use the Firmware report tool in EHX to confirm code versions. To use the Firmware
report tool:

1. Go to EHX> System> Layout.

2. Right click the matrix icon.

3. Select Firmware > Firmware report.

To check the Eclipse PiCo MVX code version only using Tera Term:

1. Install Tera Term. Tera Term is available to install from both of the Eclipse HX 7.5 DVDs:

Software DVD > 3rd_Party_Software > Teraterm

Hardware DVD > 3rd_Party_Software > Teraterm

2. Open Tera Term and select the following port settings:

Port setting

Setting to enter

Port

COM1 (Change to match a COM port present on the PC)

Baud rate

115200

Data

8 bit

Parity

None

Stop

1 bit

Flow control

none

Table 19: Tera Term port settings

3. Open the Eclipse HX-PiCo lid.

Remove power from the devices first, to avoid working with the system while it
is live. Observe all electrical shock hazard warning and precautions for
handling electrostatic sensitive devices