Clear-Com HX System Frames User Manual

Page 154

Advertising
background image

2. Fit the AES-6 card to either the

IMF-3 interface frame or Eclipse HX-Median Matrix. If there is

a jumper on J6, move the jumper to J3.Reset or power-cycle the card so the jumper change
takes effect.

3. Connect the serial cable to the front of the AES-6.

4. Run Flash Development Toolkit BASIC (FDT). Configure the FDT (Options > New Settings)

as follows:

FDT field

Setting

Select Device

H8S/2318F

Select Port

COM1 (change to match COM port present on the PC)

CPU Frequency

25.0000 MHz

Connection

BOOT mode

Recommended Speed

Deselect Use Default and set to 9600

Protection

Automatic

Messaging

Advanced

User data

Selected (Checked)

Table 43: FDT settings

5. Navigate to the AES-6 application code (*.mot format file) on the software DVD:


Software DVD > Other_Software > xxxxxxZ - AES-6 Application

Where xxxxxxZ represents the product number).

6. Select Program Flash and download the AES-6 application code (*.mot format file).

7. When the download is complete, move the jumper on J3 back to J6. Reset or power-cycle the

card.

Note:

If an FPGA image is present, the card will now run normally. If an FPGA image is not present,
you will be prompted for an FPGA image. See 3.33.1
Upgrading AES-6 FPGA.

147

Eclipse HX Upgrade Guide

Advertising
This manual is related to the following products: