Clear-Com HX System Frames User Manual

Page 68

Advertising
background image

2. Install the Renesas Flash Development Toolkit 3.4 Basic (FDT). Accept the default install

settings.

3. Start the Renesas Flash Development Toolkit 3.4 (FDT) from Programs, selecting the basic

Startup option.

4. Access the configuration (settings) dialogs, by selecting Options > New Settings...

Configure the FDT, as shown in the table below:

Settings dialog / option

Setting to enter


Select Device


H8S/2318F

Select Port

COM1 (Change to match a COM port present on the PC)

CPU Frequency

20.0000 Mhz

Connection

Boot mode

Recommended Speed

38400 (Deselect the Use-Default option)

Protection

Automatic

Messaging

Advanced

User Area

Selected (Checked)

Table 18: FDT settings

Note:

The first time the FDT is run, the settings dialogs are displayed by default. After the FDT has
been configured, the settings dialogs are no longer shown by default.

Tip:

For more information about installing and configuring the Renesas FDT, see

Appendix D: Hitachi Renesas Flash Development Tool.

5. In the Download window, click Options and ensure that:

Auto-Disconnect is selected (checked).

Download File Area has User Area selected (checked).

• The Download File radio button is selected.