Sensoface – Hach-Lange SI794 I User Manual User Manual

Page 100

Advertising
background image

100

Sensocheck

Continuously monitors the primary coil and its lines for short

circuits and the secondary coil and its lines for open circuits.

Sensocheck can be switched off. Critical values make the

Sensoface “sad” and the corresponding Sensocheck icon blinks:

Sensocheck messages are also output as error messages Err 33

or Err 34. The alarm contact is active, the red LED is lit, output

current 1 is set to 22 mA (when configured correspondingly).

Sensocheck can be switched off during configuration (then

Sensoface is also disabled).

Exception:

After a calibration a smiley is always displayed for confirmation.

Sensoface

The smiley in the display (Sensoface) alerts to sensor problems

(defective sensor, defective cable). The conditions for a friendly,

neutral, or sad Sensoface are summarized in the following chart.

Additional icons refer to the error cause.

Note

The worsening of a Sensoface criterion leads to the devaluation

of the Sensoface indicator (Smiley becomes “sad”).

An improvement of the Sensoface indicator can only take place

after calibration or removal of the sensor defect.

Advertising