Operation – Hach-Lange BUHLER 2000 Water sampler User Manual

Page 35

Advertising
background image

Operation

Page 35

Manual Bühler 2000/1029

3.3.3

**********************

01.01.2009 17:28:17
SAMPLES TOTAL
REQUESTED:

1

TAKEN:

0

**********************

By pressing the „down“ arrow key again, the „total“ number of taken
and requested samples of the running program is displayed.

3.3.4

**********************

01.01.2009 17:28:18
SAMP. CURRENT BTL
REQUESTED:

1

TAKEN:

0

**********************

Display of the taken and the requested samples of the current
bottle
.

3.3.5

**********************

PROGRAM NO. 1
INFO MEMORY

*********************

By pressing the ENT key, the menu „INFO MEMORY“ is displayed.

Here you can have a look at the stored messages.

3.3.6

**********************

PROGRAM NO. 1
BOTTLE MEMORY

**********************

By pressing the ENT key the bottle memory is displayed as follows:

- Number of the bottle
- Date and filling period (from – to)
- Total filling time
- Taken and requested samples.

With the up/down keys you can scroll to each bottle.

3.3.7

**********************

INPUT SIGNALS
FILLING LEVEL 100
FLOW ANAL. 12.2 mA
EVENT 0 / FLOW DIG 0

**********************

Display of „Input Signals“:

-

Filling level (state of level electrodes. The indicated value has no
dimension!)

-

Flow analogue

-

Event input

-

Flow digital

3.3.9

**********************

PROGRAM NO. 1

ANALOGUE FLOW
SIGNAL

**********************

By pressing the ENT key, the stored mA-signal is shown. The
values displayed are hourly average values.

3.3.10

**********************

PROGRAM NO. 1

MANUAL SAMPLE

**********************

Here you can trigger manually a single sample extraction into any
bottle (bottle No. can be selected).