Universal Error Messages:

00: Microcontroller failed to establish contact with the Digital Signal Processor. This

means that there is a hardware problem that has locked up the AB/DR-3000Õs DSP. This is
not one of those messages you want to see.

01: No Sound Loaded: The DSP was unable to find any valid sound memory. You can config-

ure the repeater, but any attempts to start it playing will just redisplay this message.

02: Invalid Spiel Zero: Requested a spiel number zero. This isnÕt a valid spiel number.

03: Invalid Spiel: Requested a spiel number which is larger than the number of spiels load-

ed on this AB/DR-3000. The request is ignored and this message is displayed.

04: Loading Defaults: This will be displayed as the AB/DR-3000 is reloading its EEPROM with

default values. This happens if you depress both the up and down buttons as the re-
peater is powered on, or if the repeater senses that the EEPROM is corrupted during
power up.

05: Error While Loading Defaults: This message indicates that the AB/DR-3000 is trying to

reload the defaults (see above), and finds that the EEPROM has been write protected. If
you ever see this message, you should power down the repeater, enable the EEPROM
writes, and apply power again. After the EEPROM is successfully reloaded and reconfig-
ured you can again disable writing to the EEPROM.

06: DMX Checksum Error: There has been an error in the incoming DMX data. Errors can

only be sensed if DMX Checksum Error checking has been turned ON.

07: Uploading Configuration through Serial Port: This message is displayed as a file is being

uploaded into the EEPROM on an AB/DR-3000.

Left (or Stereo) Channel Messages:

11: Invalid Spiel for Left: Trying to play a mono spiel on the Left side which is over the

left/right split. This will only be displayed if the left/right split has been set.

12: Ignoring an Early Start on Left (or stereo): Start ignored because the repeater is already

playing and it has been configured to ignore additional messages.

13: Storing an Early Start on Left (or stereo): Start ignored because the repeater is already

playing. The requested spiel has been stored and will be playing after the current spiel
ends.

17: Starting a spiel on the Left (or stereo) when audio is fully muted: This error message is

to remind you why you donÕt hear any sound when you start a spiel and have forgotten
to un-mute the audio first. If you have configured a spiel to start and fade in on the
same input, you will also see this message displayed, even though the sound will be-
come audible as the fade in kicks in.

Right Channel Messages:

21: Invalid Spiel for Right: Trying to play a mono spiel on the Right side which is under the

left/right split. This will only be displayed if the left/right split has been set.

22: Ignoring an Early Start on Right: Start ignored because the repeater is already playing

and it has been configured to ignore additional messages.

23: Storing an Early Start on Right: Start ignored because the repeater is already playing.

The requested spiel has been stored and will be playing after the current spiel ends.

27: Starting a spiel on the Right when audio is fully muted: This error message is to remind

you why you donÕt hear any sound when you start a spiel and have forgotten to un-
mute the audio first. If you have configured a spiel to start and fade in on the same
input, you will also see this message displayed, even though the sound will become au-
dible as the fade in kicks in.