- V

OLUME

M

ENU

-

This menu is used to set the levels of the outputs, and what sets them to that level.

-Sixteen Bit Digital Audio System rev 1.19 copyright 1996 Gilderfluke & Co. DCM-

- card __0 Volume Menu -

e) Left ramp up- 1.0 sec. | g) Right ramp up- 1.0 sec.
f) Left ramp down- 1.0 sec. | h) Right ramp down- 1.0 sec.

source/ bus controlled default upper lower current

feed channel from level limit limit level

a) Bus 1- |_mix into left_|___25__|front panel|__75%__|__99%__|__50%__|__90%__|
b) Bus 2- |send Rt. output|___22__|analog in 6|__67%__|__89%__|__45%__|__85%__|
c) Bus 3- |used by left PA|0 to 15|front panel|__99%__|__99%__|___0%__|__98%__|
d) Bus 4- |used by Rt. PA |0 to 15|front panel|__99%__|__99%__|___0%__|__95%__|

1) left volume- |fixed level|__75%__|_______|_______|__75%__|
2) left half mute- |front panel|__80%__|__90%__|__70%__|__80%__|
3) left treble- |analog in 3|__60%__|__99%__|___0%__|__65%__|
4) left bass- |ser. zone 4|__75%__|__85%__|__65%__|__70%__|
5) right volume- |DMX chanl c|__50%__|__40%__|__60%__|__51%__|
6) right half mute- |front panel|__66%__|__77%__|__55%__|__66%__|
7) right treble- |front panel|__88%__|__99%__|__77%__|__89%__|
8) right bass- |front panel|__66%__|__75%__|__50%__|__70%__|
m) more.... o) reload defaults X) eXit

please enter command-

All of the level controls can be set to be adjusted by one of the five following sources:

a)

Fixed level that will be held no matter what.

b)

Front Panel Controls. Using the ÔselectÕ button on the front of the AB/DR-3000 you can select
the control to adjust. Once selected, the Ôup/downÕ buttons are used to adjust it. You can set
the default level, as well as the upper and lower limits that the level wonÕt be allowed to go
above or below as it is adjusted. If the configuration EEPROM isnÕt write protected, the level you
set will be saved to act as the ÔdefaultÕ the next time the card is powered up.

c)

Analog Inputs. There are eight 0-10 VDC analog inputs to the DR-3000, and two on the AB-
3000. Any one of these can be used to adjust a level. You can set the upper and lower limits
that the level wonÕt be allowed to go above or below as it is adjusted.

d)

Serial Port Volume Control Zones. There are eight Ôvolume zonesÕ that can be accessed
through the serial port. These are normally used by the PA system for adjusting volumes from
the PA stations. Any one of these zones can be assigned to adjust a level on the AB/DR-3000.
You can set the default level (the level that will be assumed when the AB/DR-3000 powers up,
until it receives a volume control zone command), as well as the upper and lower limits that
the level wonÕt be allowed to go above or below as it is adjusted.

e)

DMX Channel Input. The AB/DR-3000 can listen to any four DMX-512 channels. You can as-
sign any one of these to control a level. You can set the default level (the level that will be as-
sumed when the AB/DR-3000 powers up, until it receives valid DMX-512 data), as well as the
upper and lower limits that the level wonÕt be allowed to go above or below as it is adjusted.