IAI America RCP4CR-SA7C User Manual

Page 44

Advertising
background image

1. Checking the Product

38

Ɣ SA7C, SA7R

[N]

Current Limit Value

Lead 4

Lead 8

Lead 16

Lead 24

20%

192

96

48

32

30%

288

144

72

48

40%

385

192

96

64

50%

481

240

120

80

60%

577

288

144

96

70%

673

336

168

112

* These are the reference values at 20mm/s of pressing speed.

0

100

200

300

400

500

600

700

800

Pressing Force [N]

Current-Limiting Value [%]

Lead 8

Lead 16

Lead 24

Lead 4

SA7C/SA7R Current Limiting Values and Pressing Force

0 10 20 30 40 50 60 70 80

Caution: (1) The relation of the pressing force and current limiting value is a reference. There will be a

little variance in the actual pressing force.

(2) If the current limiting value is low, the pressing force may largely vary.

(3) The movement speed at the pressing operation is fixed to 20mm/s.

The graph shows the values when pressing with 20mm/s, and it differs if the speed

changes.