IAI America RCP4CR-SA7C User Manual

Page 75

Advertising
background image

4. Maintenance Inspection

69

3) Adjust the belt tension.

Hand a cable band (thin string) on the edge of the motor unit and pull it on a tension gauge with the specified

load (specified value of the belt tension).

When the load reached the specified, tighten the screws with a 2.5mm-sized (SA5R/SA6R) or 3mm-sized

(SA7R) hex wrench to hold the unit in the place.

Belt Tension
SA5R, SA6R

25 to 30N

SA7R

80 to 90N

SA5R, SA6R

Tightening Torque : 152 N • cm

SA7R

Tightening Torque : 323 N • cm

4) Tighten the three screws to hold the pulley cover with a 1.5mm-sized hex wrench to attach the pulley

cover.

Tightening Torque : 25.4 N • cm

Cable band (thin string)

Screw

Belt Tension

Belt Tension

Pulley Cover

Screw