2. Installation

53

[5] Mounting Surface

x

The platform to install the actuator should possess a structure that ensures enough stiffness, and should

be free from vibration.

x

The surface where the actuator will be mounted should be a machined surface or that with an accuracy

equivalent to it, and the flatness should be 0.05mm/m or below.

x

Ensure a room for maintenance work.

x

The side and bottom surfaces of the base on the actuator work as the datum surfaces for the side of the

slider.

x

Use these surfaces as the datum surfaces for mounting.
















Because the side and bottom faces of the base provide reference surfaces for slider

travel as shown in the above diagram, conduct installation based on the position of

these sides when precision is required.

Follow the diagram below when installing the device using the reference surface.






Model Name A Dimensions (mm)

SA5/6

2 to 4 or less

SA7

2 to 5 or less

Datum surface

Datum surface

R0.3 or less