3 installation – IAI America RCP4CR-SA7C User Manual
Page 53

2. Installation
47
2.3 Installation
This chapter explains how to install the actuator on your mechanical system.
2.3.1
General Rules on Installation
Follow the information below when installing the actuator, as a rule.
Do pay attention to these items (except with custom-order models).
{
: Possible U : Daily inspection is required u : Not possible
Model
Horizontal
installation
Vertical installation Sideway installation
Ceiling mount
installation
SA5C, SA6C, SA7C
SA5R, SA6R, SA7R
{
{
U
U
Horizontal
Vertical
Sideways
Ceiling mount
Caution: 1. When the unit is installed vertically oriented, attempt to put the motor up unless there is a
special reason. Putting the motor on the lower side would not cause a problem in an
ordinary operation. However, it may rarely cause a problem, when it is not operated for a
long period, depending on the surrounding environment (especially high temperature),
caused by the grease being separated and the base oil flowing into the motor unit.
2. Can be installed sideways or ceiling mount, but the actuators must be checked daily. If
the actuator is installed sideways or ceiling mount, the stainless sheet may be slacked or
displaced. If the actuator is used continuously while the stainless sheet is slacked or
displaced, the stainless sheet may break or other problems may occur. Check the
actuator daily and if the stainless sheet is found slacked or displaced, make installation
adjustment of the stainless sheet. [Refer to 4.7 Procedure for Stainless Steel Sheet
Replacement and Adjustment.]