4. Maintenance Inspection

97

8) Remove the pulley case cover using two Allen wrenches, one of 2 mm across flats and the other of

3 mm across flats.

9) Connect a PC or teaching pendant to the controller to perform homing. (If the actuator is of absolute encoder

specification, an absolute reset must be performed.)

Check for deviation from the initial home position.

If there is a deviation, adjust parameter No. 22, “Home offset” if you are using an SCON controller. If you are

using an SSEL or X-SEL controller, adjust axis-specific parameter No. 12, “Home preset.” If your controller is

of absolute encoder specification, perform homing after changing the parameter, and then perform an

absolute reset.

M3 hexagon socket

head screws

M4 hexagon socket

head screws