6 replacing the motor – IAI America RCS2W User Manual

Page 93

Advertising
background image

4. Maintenance Inspection

85

Replacement motor unit

Coupling (with screws)

4.6 Replacing the Motor

4.6.1

Replacing the Motor of the Motor Straight Type (Coupling Type): RA4C Type

[Items Required for Replacement]

x

Replacement motor unit

x

Coupling (with screws)

x

Allen wrenches

x

Scale

x

Oil-based marker pen

x

Grease

Idemitsu Kosan

Daphne Eponex Grease No.2

x

PC or teaching pendant

[Overview of Replacement]

1) Move the rod to a position where Z phase turns on (home position) (2 mm from the mechanical end). In this

position, replace the motor.

2) Perform homing using a PC or teaching pendant and check for deviation from the initial home position.

If there is a deviation, adjust the home offset if you are using an SCON controller. If you are using an SSEL or

X-SEL controller, adjust the home preset.

Home position

Z phase ON

position

Mechanical end

Approx. 2 mm

The countermark on the motor

aligns with this position.

Set by the home offset parameter (SCON) or home preset

parameter (SSEL, X-SEL).

(The above value indicates the factory setting.)

1 mm

Advertising