IAI America RCS2W User Manual

Page 98

Advertising
background image

4. Maintenance Inspection

90

7) Return the coupling in the replacement motor unit to the initial motor position (Z phase position).

Align the tab on the replacement motor unit with the countermark on the cylinder. With the motor unit and

cylinder positioned this way, confirm that the orientation of the actuator coupling (adjusted to a position

corresponding to a rod projection of 2 mm from the mechanical end) corresponds to the position of the

coupling in the replacement motor unit.

Align the tab on the

replacement motor unit

with the countermark on

the cylinder.

Coupling

Replacement

motor unit

Apply countermarks on

the replacement motor

unit and coupling.

Confirm that the coupling

positions correspond.

Advertising