4. Maintenance Inspection

77

Home position Z phase ON

position

Mechanical end

Approx. 2 mm

The countermark on the motor

aligns with this position.

Set by the home offset parameter (SCON) or home preset

parameter (SSEL, X-SEL).

(The above value indicates the factory setting.)

4.5.5

Replacing the Belt: RA4R Type

[Items Required for Replacement]

x

Replacement belt

RA4R … 60S2M152R Rubber, cleanroom type (Bando Chemical Industries) 6 mm wide

x

Allen wrenches

x

Tension gauge (capable of tensioning to 7 kgf or greater)

x

Strong string, looped (or long tie-band)

x

Scale

x

Oil-based marker pen

x

PC or teaching pendant

[Overview of Replacement]

1) Move the rod to a position where Z phase turns on (home position) (2 mm from the mechanical end). In this

position, loosen the motor-unit affixing bolts and replace the belt.

2) Restore the home position.

Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust the belt to

the specified tension.

3) Perform homing using a PC or teaching pendant and check for deviation from the initial home position.

If there is a deviation, adjust the home offset if you are using an SCON controller. If you are using an SSEL or

X-SEL controller, adjust the home preset.

1 mm