IAI America MSEP User Manual

Page 105

Advertising
background image

3.4 Fieldbus

Type
Address Map

97

[Combination Example 3] When number of Simple Direct Mode axes is 2 and number of

Direct Indication Mode 6

(Extended Cyclic Setting/Number of Occupied Stations:

8 times/2 stations)

PLC ĺ MSEP

MSEP ĺ PLC

Address

Description

Address

Description

RY 000 to 01F

Gateway Control

RX 000 to 01F

Gateway Status

RY 020 to 06F

Demand Command

RX 020 to 06F

Response Command

RY 070 to 07F

Cannot be used.

RX 070 to 07F

Cannot be used.

RY 080 to 17F

Cannot be used.

RX 080 to 17F

Cannot be used.

RWw 00 to 03

Axis No.0 Control

Information

RWr 00 to 03

Axis No.0 Status

Information

RWw 04 to 07

Axis No.1 Control

Information

RWr 04 to 07

Axis No.1 Status

Information

RWw 08 to 0B

RWr 08 to 0B

RWw 0C to 0F

Axis No.2 Control

Information

RWr 0C to 0F

Axis No.2 Status

Information

RWw 10 to 13

RWr 10 to 13

RWw 14 to 17

Axis No.3 Control

Information

RWr 14 to 17

Axis No.3 Status

Information

RWw 18 to 1B

RWr 18 to 1B

RWw 1C to 1F

Axis No.4 Control

Information

RWr 1C to 1F

Axis No.4 Status

Information

RWw 20 to 23

RWr 20 to 23

RWw 24 to 27

Axis No.5 Control

Information

RWr 24 to 27

Axis No.5 Status

Information

RWw 28 to 2B

RWr 28 to 2B

RWw 2C to 2F

Axis No.6 Control

Information

RWr 2C to 2F

Axis No.6 Status

Information

RWw 30 to 33

RWr 30 to 33

RWw 34 to 37

Axis No.7 Control

Information

RWr 34 to 37

Axis No.7 Status

Information

RWw 38 to 3B

Cannot be used.

RWr 38 to 3B

Cannot be used.

RWw 3C to 3F

Cannot be used.

RWr 3C to 3F

Cannot be used.



[Combination Example 4] When number of Simple Direct Mode axes is 0 and number of

Direct Indication Mode 8

(Extended Cyclic Setting/Number of Occupied Stations:

8 times/2 stations)

PLC ĺ MSEP

MSEP ĺ PLC

Address

Description

Address

Description

RY 000 to 01F

Gateway Control

RX 000 to 01F

Gateway Status

RY 020 to 06F

Demand Command

RX 020 to 06F

Response Command

RY 070 to 07F

Cannot be used.

RX 070 to 07F

Cannot be used.

RY 080 to 17F

Cannot be used.

RX 080 to 17F

Cannot be used.

RWw 00 to 03

RWr 00 to 03

RWw 04 to 07

Axis No.0 Control

Information

RWr 04 to 07

Axis No.0 Status

Information

RWw 08 to 0B

RWr 08 to 0B

RWw 0C to 0F

Axis No.1 Control

Information

RWr 0C to 0F

Axis No.1 Status

Information

RWw 10 to 13

RWr 10 to 13

RWw 14 to 17

Axis No.2 Control

Information

RWr 14 to 17

Axis No.2 Status

Information

RWw 18 to 1B

RWr 18 to 1B

RWw 1C to 1F

Axis No.3 Control

Information

RWr 1C to 1F

Axis No.3 Status

Information

RWw 20 to 23

RWr 20 to 23

RWw 24 to 27

Axis No.4 Control

Information

RWr 24 to 27

Axis No.4 Status

Information

RWw 28 to 2B

RWr 28 to 2B

RWw 2C to 2F

Axis No.5 Control

Information

RWr 2C to 2F

Axis No.5 Status

Information

RWw 30 to 33

RWr 30 to 33

RWw 34 to 37

Axis No.6 Control

Information

RWr 34 to 37

Axis No.6 Status

Information

RWw 38 to 3B

RWr 38 to 3B

RWw 3C to 3F

Axis No.7 Control

Information

RWr 3C to 3F

Axis No.7 Status

Information

Advertising