3.8 I/O Signal Controls and Function

165

[4] Movement Command and Positioning Complete Signal (ST0 to ST2, PE0 to PE2)

PIO Signal

ST0

ST1

ST2

PE0

PE1

PE2

Operation Pattern 0 to 2

{

{

u

{

{

u

Operation Pattern 3

{

{

u

{

{

{

Operation Pattern 4

{

{

{

{

{

{

Operation Pattern 5

u

u

u

{

{

u

Ŷ Control method

1) When start signal ST* is turned ON, the actuator starts acceleration based on the data in the

specified position table for positioning to the target position.

2) Current Position No. PE* of the commanded position turns ON once the positioning is

complete.

3) Once PE* Signal turns ON, turn OFF ST* Signal.

4) Current Position No. PE* turns ON if the remaining movement amount is in the range of the

positioning width.The current position number PE* Signal will be kept on once it is turned ON

unless the start signal ST* is turned back ON, servo is turned OFF

(Note)

or the actuator is out

of the positioning width width range

(Note)

. When the pause signal *STP is turned OFF in this

condition, the current position number PE* Signal will also be turned OFF.

Caution: (1) If the ST* signal is turned ON for the position after completion of

positioning, both the PE* and PEND signals remain ON.

(2) The PE* signals is set to ON in the positioning width zone.

Accordingly, they may be turned ON under operation of the actuator

if a large positioning width is set.

(3) Interlock should be taken so that two or more ST* signals aren't set

to ON simultaneously.

• Entering the ST* signal of another position during positioning is

invalid. If the ST* signal of another position is turned ON during

positioning, the operation is terminated after the completion of the

positioning being operated.

[5] Positioning (ST0 to ST2, LS0 to LS2)

PIO Signal

ST0

ST1

ST2

LS0

LS1

LS2

Operation Pattern 0 to 2

{

{

u

{

{

u

Operation Pattern 3

{

{

u

{

{

{

Operation Pattern 4

{

{

{

{

{

{

Operation Pattern 5

u

u

u

{

{

u

Ŷ Control method

1) When start signal ST* is turned ON, the actuator starts acceleration based on the data in the

specified position table for positioning to the target position.

2) At the completion of positioning, position detection output LS* of the specified position is

turned ON.

3) Position detection output LS* is turned ON if the remaining moving distance enters into the

positioning width. LS* is set to ON if the current position is located within the positioning

width zone or OFF if the current position is located out of the positioning width zone (the

same situation occurs in the servo OFF status).

4) If the input signal method is set to continuous power supply in the initial setting, keep ST*

Signal ON until the actuator moves to another position, and turn it OFF at next ST* Signal. If

it is turned OFF with LS* Signal, the actuator decelerates and stops from the point where it

gets into the positioning width range, thus may not reach the target position. In continuous

operation, turn ON the next ST* signal by setting the positioning width within the required

precision range or setting the period taken from detection of the LS* signal to reaching the

target position.