3.8 I/O Signal Controls and Function

166

(Example) Repetition of ST1 ĺ ST2 ĺ ST1 ĺ …

Insert timer ǻt if necessary.

ǻt: Time required to certainly reach the target position after the position sensing output LS1 or 2 is turned ON.

[Example of stop position when the ST* signal is turned OFF by the LS* signal]

If the positioning width is set at a position before the original deceleration start position, the

actuator cannot reach the target position.

Caution: (1) If the ST* signal for the position is turned ON after the completion of

positioning, the LS* signal remains ON.

(2) Both the LS* and PEND signals are set to ON in the positioning width zone.

Accordingly, they may be turned ON under operation of the actuator if a large

positioning width is set.

(3) LS* signal would not be output if the positioning width is set less than the

minimum resolution.

Start signal

ST1

(PLC ĺ Controller)

Turned ON after

entering into

positioning width zone.

Target position

Position sensing output

LS1

(Controller ĺ PLC)

Start signal

ST2

(PLC ĺ Controller)

Position sensing output

LS2

(Controller ĺ PLC)

ǻt

ǻt

ǻt

Start signal

ST1

(PLC ĺ Controller)

Turned ON after

entering into

positioning width zone.

Target

position

Position sensing output

LS1

(Controller ĺ PLC)

Operation of actuator

Stop before target position

Orignal deceleration

start position

Positioning

width

Deceleration start

Speed

Move

distance