4 fieldbus type address map – IAI America MSEP User Manual
Page 149

3.4 Fieldbus
Type
Address Map
141
15) Reading of Alarm Code
PLC Output (Address n is the input and output top address for MSEP.)
(Note) If this command is sent, the response command updates with the latest information
until the demand command clear is sent.
䎃
Bit
Address
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
n+2
Demand
Command
[4001h]
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
n+3
Data 0
[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
n+4
Data 1
[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
n+5
Data 2
[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reading of
Alarm
Code
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
PLC Input (Address n is the input and output top address for MSEP.)
䎃
Bit
Address
b15 b14 b13 b12 b11 b10 b9
b8
b7
b6
b5
b4 b3 b2 b1
b0
n+2
Response
Command
[4001h]
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
n+3
Data 0
[0]
–
–
–
–
–
–
–
–
128
64
32
16
8
4
2
1
n+4
Data 1
[Alarm Code]
n+5
Data 2
[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reading of
Alarm
Code
n+6
Data 3
[Axis No.]
–
–
–
–
–
–
–
–
–
–
–
–
–
4
2
1
1 word = 16 bit
1 word = 16 bit