3 circuit diagram, Power supply and emergency stop, Chapter 2 wiring – IAI America MSEP User Manual

Page 50: Sample circuit diagrams are shown below

Advertising
background image

Chapter 2 Wiring

42

2.3 Circuit Diagram

Sample circuit diagrams are shown below.

[1]

Power Supply and Emergency Stop



The diagram shown below is an example of a circuit for when reflecting the emergency stop

switch on a teaching pendant to the emergency stop circuit of the system.

Note 1 When the teaching pendant is not connected, S1 and S2 become short-circuited inside the controller.

Note 2 When the motor power must be disconnected externally for safety category compliance, apply a safety rated

contactor between MPISLOT* and MPOSLOT*. Choose one that is capable to open and close with the motor

current consumption of the connected actuator [Refer to 1.2 List of Basic Specifications.].

Note 3 The rating for the emergency stop signal (EMG-) to turn ON/OFF at contact CR1 is 24V DC and 10mA.

Note 4 For CR1, select the one with coil current 0.1A or less.

Note 5 If supplying power with using a 24V DC, having it turned ON/OFF, keep the 0V connected and have the +24V

supplied/cut (cut one side only).

Note 6 By cutting out the connection between EMG+SLOT* and EMGINSLOT*, only the disconnected slot number can be

made in the condition of an emergency stop. (*: Slot Number)

EMGINSLOT0

EMGINSLOT1

EMGINSLOT2

EMGINSLOT3

Emergency Stop

Reset Switch

Emergency Stop

Switch

CR1

SIO Connector

CR1

24V

0V

Emergency Stop Control Circuit

Motor Power Supply (Slot 3)

(Axis No.6 and 7)

MPISLOT3

MPOSLOT3

CR2

(Note 2)

MPISLOT2

MPOSLOT2

CR2

(Note 2)

MPOSLOT1

MPISLOT1

CR2

(Note 2)

MPISLOT0

MPOSLOT0

CR2

(Note 2)

Motor Power Supply (Slot 2)

(Axis No.4 and 5)

Motor Power Supply (Slot 1)

(Axis No.2 and 3)

Motor Power Supply (Slot 0)

(Axis No.0 and 1)

MP+24V

0V

CP+24V

0V

Control

Power

External Drive Cutoff •

Emergency Stop Input Connector

Power Line Input Connector

EMG+SLOT0

(Note 6)

S1

4
3

2
1

12
11

10
9

7
8
5
6

15
16
13
14

1
3

4

2

Emergency Stop Switch on

Teaching Pendant

S2

(Note1)

EMG A

EMG B

MSEP

8

5

EMG-

EMG+SLOT1

(Note 6)

EMG+SLOT2

(Note 6)

EMG+SLOT3

(Note 6)

3

2
4

CR1

(Note 4)

CR2

(Note 2)

CR1

System I/O Connector

Advertising