3.8 I/O Signal Controls and Function

171

[9] Pause during Movement = Operation Timing for Operation Patterns 0 to 2

(1) Single Solenoid System:

With the input of the pause signal (*STP), the actuator pauses its operation. Shown below is

an example for the forward end position movement.

Pause signal (*STP)

Movement command (ST0)

Forward end point positioning completion output (PE1)

Forward end position detection output (LS1)

Actuator operation

Pause

Forward end

Positioning width

(Parameter No.1)

(2) Double Solenoid System:

By turning both ST0 and ST1 OFF, the operation of the actuator is paused. Shown below is

an example for the forward end position movement.

Forward end point positioning completion output (PE1)

Forward end position detection output (LS1)

Backward end movement signal (ST0)

ST0 and ST1 are OFF

Forward end movement signal (ST1)

Actuator operation

Pause

Forward end

Positioning width

(Parameter No.1)

[10] Speed Change during Movement = Operation Timing for Operation Patterns 1

(1) Single Solenoid System:

With the movement speed change signal (SPDC) turned ON, the actuator is operated with

the changed speed from the position set as the change position in the position data. Shown

below is an example for the forward end position movement.

Forward end point positioning completion output (PE1)

Forward end position detection output (LS1)

Movement signal (ST0)

Movement speed change signal (SPDC)

Actuator operation

Position set in change position

Forward end

Positioning width

(Parameter No.1)