IAI America MSEP User Manual
Page 200

3.10 Status LED
192
7) For Fieldbus Type MECHATROLINK
{
: Illuminating, ×: OFF
Symbol
Lamp
Condition
Color
Description
Green Ready
Orange Alarm generated
SYS
(System status)
×
–
Power is OFF or in initializing
Red
Alarm generated
EMG
(Emergency stop
status)
×
–
Normal
Green AUTO Mode
MODE
(AUTO/MANU status)
×
–
MANU Mode
Orange Controller internal communication error
T ERR
(Controller internal
communication status)
×
–
Normal
Orange Fieldbus communication error
C ERR
(Fieldbus
communication status)
×
–
Normal
Green Receiving CONNECT, Communicating
Orange
Communication error detected (self-station
receiving status error, synchronizing frame status
error)
STS1
×
–
DISCONNECT received in initializing process
Green Initializing complete in normal condition
Orange Initializing failed (RAM check error)
STS0
×
–
Initializing started
SYS
EMG MODE
T C ERR
0 1