Chapter 1 Specifications Check

22

1.2 List of Basic Specifications

Specification Item

Driver for Servo Motor

Driver for Pulse Motor

Number of Controlled Axes

MAX. 8 axis

Control/Motor Power Supply Voltage

24V DC ±10%

Brake Power Supply

0.15A × Number of axes

Control Power Current Consumption

0.8A

Control Power In-Rush Current

MAX. 5A 30ms or less

Motor type

Rated

Low

power

MAX.

(Note 1)

Motor flange

size

Rated

MAX.

(Note 2)

2W

0.8A

4.6A

20P

1.0A

2.0A

5W

1.0A

6.4A

28P

1.0A

2.0A

10W (RCL)

6.4A

10W (RCA/RCA2)

1.3A

2.5A

4.4A

35P

2.0A

2.0A

20W

1.3A

2.5A

4.4A

20W (20S type) 1.7A

3.4A

5.1A

42P

2.0A

2.0A

Motor Current Consumption

30W

1.3A

2.2A

4.4A

56P

2.0A

2.0A

Motor Power In-Rush Current

Number of slots × MAX. 10A 5ms or less

Controller Heat Generation

26W

Control System

Vector control

Weak field-magnet vector control

RCA, RCP2, RCP3, RCP4 All types

800Pulse/rev

RCA2-ƑƑƑN

1048Pulse/rev

RCA2

Other than RCA2-ƑƑƑN

800Pulse/rev

RA1L • SA1L • SA4L • SM4L

715Pulse/rev

RA2L • SA2L • SA5L • SM5L

855Pulse/rev

Encoder

Resolution

RCL

RA3L • SA3L • SA6L • SM6L

1145Pulse/rev

Actuator Cable Length

MAX. 20m (Note) 10m maximum for Simple Absolute type

Serial Communication

(SIO Port: Only for teaching)

RS485 1CH (complying with Modbus Protocol) Speed 9.6 to 230.4kbps

PIO Type

PIO Type: Signal I/O dedicated for 24V DC (to be selected when purchased NPN/PNP)

Number of max. input: 4 points per axis, Number of max. output: 4 points per axis

Cable length MAX. 10m

External Interface

Fieldbus Type

DeviceNet

(Note)

, CC-Link, PROFIBUS-DP, CompoNet, MECHATROLINK, EtherNet/IP

and EtherCAT [Refer to Section 1.4 Specifications for each Fieldbus.]

An operation by RC Gateway Function is available. Refer to the other instruction

manual for more details.

Data Setting and Input

PC software, Touch panel teaching, Gateway parameter setting tool

Data Retention Memory

Position data and parameters are saved in the nonvolatile memory. (There is no

limitation in number of writing)

Positioning Points

PIO Type: 2 or 3 points

Fieldbus Type: 256 points (There is no limit for simple direct and direct indication modes)

(Note) The number of positioning points differs depending on the operation mode

select by the parameter setting.

LED Display (mounted on Front

Panel)

8 LED lamps for driver status display (for each driver board)

Status LED 4 points (PIO type), 7 points (Fieldbus type)

Forcibly Releasing of Electromagnetic

Brake

Can be released with the forcibly releasing signal input (24V DC input) to each axis

Protective Functions

(Note 3)

Overcurrent Protection (Equipped with a built-in cutoff circuit using a semiconductor

for each slot)

Protection Function against Electric Shock Class I basic insulation
Insulation Resistance

500V DC 10M:

Weight

620g, For simple absolute type, 690g plus 1950g for absolute battery box (for 8-axis type)

Cooling Method

Forced air-cooling

External Dimensions

123W × 115H × 95D

Advertising