(6) Range

- As for the range, depending on the setting in the push as either 0 or other than 0, this

function will vary. [mm]
(A) Push = 0 (Positioning Mode)

- The positioning mode uses range value as a location to turn ON the position complete

output prior to reaching the actual data.

The default value will depend on the actuator type. (see diagram A).

(B) Push

≠ besides 0 (Push Mode)

- The push mode uses the range value as the distance of the push. [mm]

- When the push direction is towards home, a “minus” sign should be placed in the range

column.

Diagram A

Diagram B


(7) MAX

Acceleration

- Selects either the assigned acceleration or the maximum acceleration. Inputs are either 1

or 0. The default value is set as 0.
0: Assigned

acceleration

The value placed in (4) will be used as the actual acceleration value and
deceleration value.

1:

Maximum

acceleration

This will automatically utilize the maximum acceleration matched to the load.
Deceleration remains as the assigned value in (4).


(8) ABS/INC - Select either the absolute or incremental positioning.

0: Absolute positioning (ABS)
1: Incremental positioning (INC)
The default value is absolute positioning (ABS).

Speed

Speed

(5) When push = 0

(2) Distance up to the position

(5) When push

≠ 0

(2) Distance up to the position

Transfer distance

Transfer distance

(6) Range Value

(6) Range Value

(7) When acceleration only MAX = 0

(4) The value set in

acceleration/deceleration

(7) When acceleration only MAX = 1

Transfer
distance

Transfer
distance

The maximum acceleration
matches the load

(4) The value set in
acceleration/deceleration

Speed

Speed

Advertising