(1) Clear:

The Clear operation procedure is explained below. The data of any position number is cleared.
In this example, the data of position number 1 is cleared.
The position data table becomes as shown below.

No. Position

Vel

Acc

Dcl

Push

LoTh

Range

Zone +

Zone -

Acc/Dcl

Mode

ABS/INC

Cmnd

Mode

Stop

Mode

0 0.00

125

mm/s

0.20 G

0.20 G

0 %

0 %

0.10 mm

0.00

mm

0.00

mm

0 0 0 0

1 50.00

100

mm/s

0.10 G

0.10 G

0 %

0 %

0.20 mm

0.00

mm

0.00

mm

0 0 0 0

2 80.00

100

mm/s

0.10 G

0.10 G 40 %

0 %

5.00 mm

0.00

mm

0.00

mm

0 0 0 0

3 10.00

20

mm/s

0.20 G

0.20 G

0 %

0 %

0.10 mm

0.00

mm

0.00

mm

0 1 0 0

No. Position

Vel

Acc

Dcl

Push

LoTh

Range

Zone +

Zone -

Acc/Dcl

Mode

ABS/INC

Cmnd

Mode

Stop

Mode

0 0.00

125

mm/s

0.20 G

0.20 G

0 %

0 %

0.10 mm

0.00

mm

0.00

mm

0 0 0 0

1

*

* mm/s

* G

* G

* %

* %

* mm

* mm

* mm

*

*

*

*

2 80.00

100

mm/s

0.10 G

0.10 G 40 %

0 %

5.00 mm

0.00

mm

0.00

mm

0 0 0 0

3 10.00

20

mm/s

0.20 G

0.20 G

0 %

0 %

0.10 mm

0.00

mm

0.00

mm

0 1 0 0


















Slct Mode/M2

A. 00

* Edit

In the Mode Select Screen, using the

keys, select Edit and then, press the Return key.

Edit A.

00

* Clear

In the Teach/Play screen, using the

keys,

select Clear and then, press the Return key.

Using the

keys, change the position number

into 1. Pressing 1 on the Numeric keys will clear
position number 1 and then, the screen will return to
the Edit Screen. To cancel, press 0.
In either case, the screen will return to the previous
screen.

Edit A.

00

* Clear

Slct Mode/M2

A. 00

* Edit

Press the

key once to return the screen to the

Mode Select Screen.

Clear?

No. 001

A. 00

50.00

Y

Æ

1 N Æ 0

Position number 1

Position data for