62

Appendix

* Appendix
Parameter (factory-installed) initializing method

Parameter is changed to the factory-installed parameter. (Initialization)
Models of PCON, ACON, SCON, ERC2 are available for this method.

Caution: Note that the parameter set by the user is changed to the factory-installed parameter if the

parameter (factory-installed) is initialized.





















(Note)

Unless the software was reset, the parameters were rewritten to factory-installed
parameters, however, operation is not performed with factory-installed parameters.
The parameters are enabled after the next reset or after power is turned on.

Slct Mode/M2

A. 00

* User Adjust

In the mode select screen, using the

keys,

set the user adjustment, and then press the Return
key.

User Adjust

A. 00

Adjust 5119

Input 5119 into the adjustment number, and press the
Return key.

Ship Para

A. 00

* Reset?

Y Æ 1 N Æ 0

When initializing the parameter (factory-installed),
press the

key.

When initialization of the parameter (factory-installed)
is completed, the screen moves to the software reset
screen. (When interrupting, press the

key. The

screen returns to the mode select screen.)

Soft Reset

A. 00

* Reset?

Y Æ 1 N Æ 0

When executing software reset, press the

key.

(When interrupting the software reset, press the

key. The screen returns to the mode select screen.)