IAI America RCM-E User Manual

Page 58

Advertising
background image

50












Sets the current limit value when positioning stops.

User Parm 12

A. 00

Hold Cur

5%

Sets the current limit value when homing is carried
out.

User Parm 13

A. 00

Home Cur

10%

Selects and sets the SIO communication speed.

User Parm 16

A. 00

Baud 38400bps

Sets the slave station transmitter activation minimum
delay time.

User Parm 17

A. 00

RTIM 5 msec

Sets the servo ON input [0: enable/1: disable].

User Parm 21

A. 00

SON Disable

1

Sets the homing offset amount.

User Parm 22

A. 00

OFST 0.20mm

Sets the zone limit 2 + side.

User Parm 23

A. 00

+ Zone 2

9999.99mm

Sets the PIO pattern.

User Parm 25

A. 00

PIO Ptn

0

Sets the excitation phase signal detection operation
initial move direction [0: reverse/1: normal].

User Parm 28

A. 00

Pole Sense Dir

0

Sets the excitation phase signal detection time.

User Parm 29

A. 00

Pole Sense

10msec

Sets the speed loop proportional gain.

User Parm 31

A. 00

Prop Gain

103

Sets the zone limit 2

− side.

User Parm 24

A. 00

- Zone 2

9999.99mm

Sets the speed loop integral gain.

User Parm 32

A. 00

Int Gain

3146

Sets the torque filter time constant.

User Parm 33

A. 00

Trq Filter

0

Sets the push speed.

User Parm 34

A. 00

Push Vel

2mm/s