29






Input using position number 1



































MDI

No. 000

A. 00

Vel 125 mm/s

MDI

No. 001

A. 00

Position A

*

MDI

No. 001

A. 00

Position A

50

MDI

No. 001

A. 00

Vel 100 mm/s

The screen will turn into the Input Screen for Speed.
The default value will be utilized as is. Since other
data will use the default value, input for position
number 0 will end here.
Next, position number 1 input will be executed.

Press the

key to advance the position number to

1.

The screen will turn into the Input Screen for Position.
Use the Numeric keys to input 50 and then, press the
Return key.

The screen will turn into the Input Screen for Speed.
Use the Numeric keys to input 100 and then, press
the Return key.

Position number 1

MDI

No. 001

A. 00

Acc 0.1

G

The screen will turn into the Input Screen for Acc.
Use the Numeric keys to input 0.1 and then, press the
Return key.

MDI

No. 001

A. 00

Push %

0

%

The screen will turn into the Input Screen for Push %.
The default value will be utilized as is, so press the
Return key.

MDI

No. 001

A. 00

LoTh 0

%

The screen will turn into the Input Screen for Range.
The default value will be utilized as is, so press the
Return key.

MDI

No. 001

A. 00

Range 0.2mm

The screen will turn into the Input Screen for Range.
Use the Numeric keys to input 0.2 and then, press the
Return key.

MDI

No. 001

A. 00

Zone +

0.00mm

The screen will turn into the Input Screen for Zone +.
The default value will be utilized as is, so press the
Return key.

MDI

No. 001

A. 00

Zone -

0.00mm

The screen will turn into the Input Screen for Zone -.
The default value will be utilized as is, so press the
Return key.

MDI

No. 001

A. 00

ABS Æ 0

INC Æ 1

0

Input for position number 1 will end here.
Next, position number 2 input will be executed.

MDI

No. 001

A. 00

Acc/Dcl

0

The screen will turn into the Input Screen for Acc •
Dcl. The default value will be utilized as is, so press
the Return key.

MDI

No. 001

A. 00

Dcl 0.1

G

The screen will turn into the Input Screen for Dcl. Use
the Numeric keys to input 0.1 and then, press the
Return key.