1 Monitoring with WindO/I-NV2

25

Monitor F

unction

4

On the Online tab, in the Monitors group, click Open Current Screens.
The screen displayed on MICRO/I opens in the editing window.

5

On the Online tab, in the Monitors group, select the monitor being used.
When monitoring starts, the screen monitor is displayed.

■

Screens
Automatically checks device addresses used on the screen displayed on the MICRO/I. For details, refer to “Screen
Monitor” on page 25-6.

■

Object List
Displays values of devices in a popup on the Object List window. It also highlights objects while satisfying
conditions. For details, refer to “1.3 Display the Value of Device in Popup” on page 25-16, and “1.4 Highlighting
Objects While Satisfying Conditions” on page 25-16
.

■

Custom
Registers monitored devices individually and displays the value of devices. For details, refer to “Custom Monitor” on
page 25-7.

■

Batch
Registers monitored devices as a batch for sequential addresses and displays the value of devices. For details, refer to
“Batch Monitor” on page 25-14.

■

Hosts
Displays the state of external devices connected to the MICRO/I. For details, refer to “External Device Monitor” on
page 25-15.

6

Check operation of project data by monitoring and changing values of devices, and edit project data if there is an
error.

If the monitored screen is switches, repeat steps

3

through

4

.

7

Download the edited project data to the MICRO/I.

8

On the Online tab, in the Monitors group, click Stop Monitor.

To reflect edits made during debugging, it is necessary to perform a download.

To switch from simulation mode to monitor mode, on the Online tab, in the Monitors group, click Stop