IDEC High Performance Series User Manual
Page 154

5 User Communication
3-52
WindO/I-NV2 User’s Manual
Constant (Hexadecimal)
The received data is considered as hexadecimal data and compared with the data specified without being converted.
Use this setting to receive a control code of ASCII data (00h to 1Fh).
This can be configured only when RXD is selected in Command Type on the Command Settings dialog box, and
Constant (Hexadecimal) is selected under Type on the Data Settings dialog box.
■
Data
Enter hexadecimal data designated to be received.
Example: Constant (Hexadecimal) for receive command data
When the trigger condition is satisfied, the received data is compared with the following data.
HG2G-S/-5S/-5F, HG3G/4G:
1 to 1,500 bytes
HG1F/2F/2S/3F/4F:
1 to 500 bytes
When a Constant (Character) is set at the beginning of a command, the first one byte is recognized as the
start code. When a Constant (Character) is set at the end of a command, the last one byte is recognized as
the terminal code.
For details, refer to “Start Code and Terminal Code” on page 3-67.
Item
Setting
Data
1234
1234h
No conversion
12h
Data used for comparison with received data
Specified data
34h
Order of reception