background image

112

CATC M

ERLIN

S

W

AND

2.00

C

HAPTER

A

User’s Manual

Command Generator Command Descriptions

Read_Loopback_Mode

Read_Loopback_Mode will read the value for the setting of the Merlin’s
Wand Host Controller’s Loopback_Mode. The setting of the
Loopback_Mode will determine the path of information.

Write_Loopback_Mode

The Write_Loopback_Mode will write the value for the setting of the Host
Controller’s Loopback_Mode into Merlin’s Wand.

CATC-Specific HCI Commands

CATC_BER_Test

This command will measure Bit Error Rate (BER) when fully loaded DH1,
DH3, DH5, DM1, DM3 or DM5 packets are sent from master to slave on
the link.

Command Parameters

Examples

Comments

N/A

Return Events

Read_Loopback_Mode_Complete

Read_Loopback_Mode_Error

Command Parameters

Examples

Comments

Loopback_Mode

0

0x00=No Loopback mode
enabled. Default

0x01=Enable Local
Loopback

0x02=Enable Remote
Loopback

Return Events

Write_Loopback_Mode_Complete

Write_Loopback_Mode_Error

Command Parameters

Examples

Comments

HCI_Handle

Number_Of_Packets

0000

0x0000=Unlimited number
of packets will be sent

0x0001=0xFFFF number of
packets will be sent